Flux calibration data for each receptor.
More...
#include <FluxCalibratorPolicy.h>
|
|
| Policy () |
| | Default constructor.
|
|
virtual Policy * | clone () const=0 |
| | Return a new default constructed copy of self.
|
|
virtual void | integrate (Signal::Source source, unsigned ireceptor, const Estimate< double > &cal_hi, const Estimate< double > &cal_lo)=0 |
| | Integrate an observation of the reference source.
|
|
void | get (std::vector< Estimate< double > > &S_sys, std::vector< Estimate< double > > &S_cal) const |
| | Get the flux densities for each receptor.
|
|
void | set (const std::vector< Estimate< double > > &S_sys, const std::vector< Estimate< double > > &S_cal) |
| | Set the flux densities for each receptor.
|
|
virtual void | set_nreceptor (unsigned) |
| | Set the number of receptors.
|
|
unsigned | get_nreceptor () const |
| | Get the number of receptors.
|
| void | set_S_std (double S_std) |
| | Set the flux density of the standard candle.
|
| double | get_S_std () const |
| | Get the flux density of the standard candle.
|
|
void | set_valid (bool f=true) |
| | Set the data validity flag.
|
|
bool | get_valid () const |
| | Get the data validity flag.
|
|
bool | get_solution_available () const |
| | Return true when a solution is available.
|
|
Estimate< double > | get_S_sys () const |
| | Return the total system equivalent flux density.
|
|
Estimate< double > | get_S_sys (unsigned receptor) const |
| | Return the system equivalent flux density in the specified receptor.
|
|
Estimate< double > | get_S_cal () const |
| | Return the total calibrator flux density.
|
|
Estimate< double > | get_S_cal (unsigned receptor) const |
| | Return the calibrator flux density in the specified receptor.
|
|
| Able (const Able &) |
|
Able & | operator= (const Able &) |
|
unsigned | get_reference_count () const |
|
| HeapTracked (const HeapTracked &) |
|
HeapTracked & | operator= (const HeapTracked &) |
|
bool | __is_on_heap () const |
|
|
void | calculate () const |
| | Calulate S_cal and S_sys for both receptors.
|
|
virtual void | compute (unsigned ireceptor, Estimate< double > &S_cal, Estimate< double > &S_sys)=0 |
| | Compute the fluxes of the reference source and system.
|
|
Handle * | __reference (bool active) const |
|
void | __dereference (bool auto_delete=true) const |
|
|
bool | valid |
| | Flag set when data are valid.
|
|
double | S_std |
| | Flux density of the standard candle.
|
|
std::vector< Estimate< double > > | S_cal |
| | Calibrator flux density in each receptor.
|
|
std::vector< Estimate< double > > | S_sys |
| | System equivalent flux density in each receptor.
|
|
bool | calculated |
| | Flag set when S_cal and S_sys have been computed.
|
Flux calibration data for each receptor.
◆ get_S_std()
| double Pulsar::FluxCalibrator::Policy::get_S_std |
( |
| ) |
const |
Get the flux density of the standard candle.
Get the flux of the standard candle.
◆ set_S_std()
| void Pulsar::FluxCalibrator::Policy::set_S_std |
( |
double | S_std | ) |
|
Set the flux density of the standard candle.
Set the flux of the standard candle.